MThings
MThings
MODBUS industrial control host computer software, covering SCADA monitoring, historical data collection, industrial alarm, logic control and data gateway scenarios.

Professional MODBUS Industrial Control Host Computer Software
Focused on real-time operation and maintenance, rapid deployment and multi-scenario coverage, balancing universal platform and on-demand customization capabilities.
Download
Get MThings, Start Instantly
Download the latest desktop installer package, view release notes, and prepare your devices in minutes.
Windows Installer
Windows 7 and above, dual-core 1.5GHz, 2GB RAM, 200MB storage, 1024x768, with serial or Ethernet port.
Download for WindowsAutomation Configuration Skill
No onboarding required, integrate with major platform agents to generate engineering configuration files in one click.
Download Skill FileUser Manual
View operation guides, feature descriptions, and common issue troubleshooting for daily use.
User ManualProduct White Paper
Learn about product architecture, core capabilities, supported scenarios and deployment recommendations.
View White PaperEngineering-grade MODBUS Host Computer Software
Choose the version according to your usage scenario, from free personal debugging and testing to licensed commercial deployment and system integration.
Personal Use, Permanently Free
Suitable for MODBUS debugging, simulation, testing and learning.
Built-in simulated master and slave
Supports 4 types of MODBUS address read/write
Supports MODBUS ASCII, RTU, TCP and TCP/UDP passthrough
Supports multi-device, multi-channel, curves and packet parsing
For Enterprise Deployment and Commercial Applications
Suitable for long-term operation, monitoring and control scenarios.
Historical data, SCADA monitoring, real-time alarm
Logic control, data gateway, MQTT forwarding
Compatible with PLC, meters, inverters and other industrial devices
Free for personal use, licensed for commercial use
Personal vs Commercial Edition
| Feature | Personal | Commercial |
|---|---|---|
| Target Users | For personal use | For industrial and commercial users |
| Licensing | Features permanently free | Paid license, one-time purchase, lifetime validity |
| Technical Support | Not provided | After-sales technical support provided |
| Usage Responsibility | No liability for any usage consequences, and the built system is prohibited from commercial use | Can be used for commercial applications after licensing |
| System SCADA | Supported | Supported |
| Logic Control | Supported | Supported |
| Historical Data | Only one master device | Supported |
| Alarm Data | Up to 3 alarm configurations | Supported |
| Data Gateway | Not supported | Supported |
| MQTT Forwarding | Not supported | Supported |
| Linux | Not supported | Custom deployment |
| Channel Management | Supported | Supported |
| Device Management | Supported | Supported |
| User Management | Supported | Supported |
| Device Data | Supported | Supported |
| Simulated Master | Supported | Supported |
| Simulated Slave | Supported | Supported |
| Real-time Data Curve | Supported | Supported |
| Link Statistics | Supported | Supported |
| Packet Test | Supported | Supported |
| Auxiliary Tools | Supported | Supported |
Services
Professional Services for Engineering Delivery
Custom Software Development
Provide customized software development services for project requirements and deployment scenarios.
Engineering Point Configuration
Assist in completing device point tables, communication mapping and engineering configuration planning.
SCADA Design
Provide interface structure, screen layout and industrial control visualization design support.
Software Training
Provide product onboarding, operation guidance and project team usage training.
FAQ
Frequently Asked Questions
Answers to common questions about MODBUS support, edition differences, historical data, alarms and industrial deployment scenarios.
What MODBUS protocols does MThings support?
MThings supports MODBUS ASCII, RTU, TCP and TCP/UDP passthrough, suitable for debugging and integration with PLCs, meters, inverters and other devices.
What's the difference between Personal and Commercial editions?
The Personal edition is suitable for personal debugging, simulation, testing and learning, and can be used for free. The Commercial edition is for enterprise deployment, adding SCADA monitoring, historical data, industrial alarm, data gateway and other commercial capabilities.
Does MThings support historical data and alarm handling?
Yes. The Commercial edition supports historical data collection and storage, real-time alarm handling, and logic control scenarios, suitable for continuous operation industrial monitoring projects.
What industrial devices and deployment scenarios is it suitable for?
MThings can be used with PLCs, meters, inverters, touch screens, industrial PCs and other industrial control devices, suitable for MODBUS monitoring, on-site debugging and data gateway projects.
FAQs and Skills
FAQs and Skills